Login
Start Free Trial Are you a business? Click Here

Little Giant 554405 Automatic Condensate Removal Pump with Safety Switch, 65 gph, 11" x 5" x 7", ABS Reviews

4.9 Rating 303 Reviews
Read Plumbing Supply and More Reviews

The Little Giant VCMA-15ULS Model 554405 represents precision-engineered condensate management designed for residential and light commercial HVAC applications where automatic water removal prevents equipment damage and maintains continuous operation. This vertically-oriented pump features a 1/50 horsepower motor delivering 65 gallons per hour at one foot of lift, combined with a half-gallon ABS reservoir and dual-purpose safety switch protecting expensive air conditioning, high-efficiency furnace, and dehumidifier installations from overflow-related failures. Measuring exactly 11 inches in length, 5 inches in width, and 7 inches in height, this compact unit weighs 4.6 pounds and occupies minimal mechanical room space while providing fifteen-foot maximum shut-off head capability. The factory-installed six-foot grounded power cord with three-prong NEMA 5-15P plug eliminates extension cord requirements, while three strategically-positioned 1-1/8 inch diameter inlet openings accommodate multiple condensate sources simultaneously without requiring additional plumbing modifications or custom drainage configurations for multi-zone climate control systems. Vertical Centrifugal Design & 1/50 HP Motor Engineering for Condensate-Specific Performance Applications The MPN 554405 employs specialized vertical centrifugal pump architecture where the motor mounts directly above the collection reservoir, creating a self-contained footprint measuring under one square foot while delivering sufficient discharge pressure to overcome fifteen feet of vertical lift. This 1/50 horsepower high-performance motor operates at 115 volts, 60 Hz, consuming just 60 watts and drawing only one amp during active pumping cycles, making it compatible with standard residential electrical circuits without requiring dedicated breaker installations or electrical service upgrades. Built-in thermal overload protection automatically de-energizes the motor when internal temperatures exceed safe operating thresholds, preventing winding damage from prolonged run conditions caused by discharge line blockages or excessive back pressure. The motor drives a glass-filled polypropylene impeller through a corrosion-resistant stainless steel shaft extending downward into the molded ABS volute chamber, where centrifugal force propels condensate through the integrated 3/8-inch barbed discharge adapter at flow rates reaching 65 gallons per hour under typical installation conditions with minimal head pressure. Half-Gallon ABS Tank Construction with Triple Inlet Configuration & Wall-Mounting Provisions The permanently-sealed half-gallon collection reservoir fabricated from ABS thermoplastic provides exceptional chemical resistance against the slightly acidic condensate produced by high-efficiency gas furnaces while remaining impervious to corrosion, rust formation, and degradation from continuous water exposure throughout the pump's operational lifespan. This leakproof tank incorporates molded-in structural reinforcement ribs preventing flexing under full load conditions, with integrated wall-mounting tabs cast directly into the housing allowing secure vertical or horizontal installation using standard fasteners. Three separate 1-1/8 inch diameter inlet openings positioned around the tank perimeter enable contractors to connect condensate drain lines from air conditioning evaporator coils, furnace secondary heat exchangers, and auxiliary dehumidification equipment without installing additional manifolds or junction boxes. Two inlet ports feature removable threaded cap plugs maintaining watertight seals when unused, while the primary inlet remains permanently open for the main condensate source, accommodating flexible vinyl tubing, rigid PVC pipe connections, or direct insertion of manufacturer-supplied drain lines depending on specific installation requirements.

Visit Product Page
“to be kept as a backup for the same one on the furnace now.”
Helpful Report
Posted 3 years ago
“It came as advertised in a timely manner. I did not need to install. The return practice seemed cumbersome. I made a request, received a page to include with the shipment. I did so, sealed it up. That night, I got another mailing with different documents. I have my box sealed, ready to go, but never used the second set of documents. I'm unsure why the delay in the second set. I may just discard to trash, or find somebody to give it away.”
Helpful Report
Posted 3 years ago
“It is used in an outdoor fountain. I completely clean and dry it out at the end of the season and it stays outdoors covered. It is a great product and lasts for years.”
Helpful Report
Posted 3 years ago
“exact replacement for my heating system. Received quickly. You guys rock saved me time and money.”
Helpful Report
Posted 3 years ago
“Hubby and I installed this pump to replace an older version “Little Giant” that wouldn’t shut off. I also bought 50’ of vinyl 3/8” I.D. tubing for our 6’ vertical, 35’ total run and an extra check valve. I ordered the pump from plumbingsupplyandmore on a Saturday for $30 retail with free shipping and it arrived Monday afternoon, which was great except it was shipped unsealed in its product box, only. All the parts including manual were intact and undamaged, which was a marvel. The new pump measures a bit larger than the old, so hubby had to drill new mounting holes. A tip we learned from a FB video only after having considerable trouble measuring and drilling in a low, cramped, and dim location (we’re both old and arthritic 🙂), is to affix a long strip of painter’s tape across both mounting brackets on the rear of the unit and poke holes through the tape at the two brackets. Remove the tape and apply it to the mounting wall at your desired location, ensuring that the tape placement is level. Drill through the two holes in the tape. Remove the tape and insert your mounting screws.Being a thrifty DIY person, I investigated why the old pump failed to shut off. I suspected a stuck float or a clogged check valve. I disassembled the old pump tank and check valve and discovered the tank bottom was covered an inch-thick with nasty-looking rust-colored debris that also clogged the pump underside and the check valve. After scraping out as much of this crud as possible, I filled the tank with an Iron-Out solution, set the unit in place on the tank, soaked the rust-coated pump underside and check valve for several days, cleaned and re-assembled the unit. Several test runs confirmed that both the old pump and the check valve now operate good as new, so we’ll keep the unit for emergencies. Both the new and the old pumps discharge in about 10 seconds each, leaving about an inch of water in the tanks. Lesson learned: I’ll put the new pump on a regular cleaning schedule. The manual recommends a cleaning with every furnace filter change.”
Helpful Report
Posted 3 years ago
“Does exactly what it's supposed to”
Helpful Report
Posted 3 years ago
“Works well, reasonable price and easily installed”
Helpful Report
Posted 3 years ago
“This replaced the same model which operated for more than ten years without any problems. I was very impressed by the quick delivery.”
Helpful Report
Posted 3 years ago