3/4" Cartridge Circulator Pump, 0 to 17 gpm, 115 VAC Reviews

4.9 Rating 381 Reviews
Used to add zone to hydronic heating system, have used many over the years, all have been very reliable and long lasting.
Helpful Report
Posted 4 years ago
Direct replacement without any modification
Helpful Report
Posted 4 years ago
I just replaced this pump after 14 years on my outdoor wood boiler. The new one is the high efficiency 0015 model. I hope it lasts as long.
Helpful Report
Posted 4 years ago
Once you know what you are doing, very easy installation. Just 4 bolts. The problem is installation information is extremely hard to come by. So after watching hours of videos, thought I'd share my tips for what should be a 15-minute install. 1) need figure out if the circulating pump you are replacing is on the RETURN side, or the FEED / SUPPLY side. This should be easier to know then it is for a novice like me. An hour of research revealed my RETURN side pipes came back into the lower half of my oil-fired boiler. My SUPPLY side had an air vent and expansion tank connected to the pipe run and exited to top half of the boiler. 2) with that finally determined I realized my pump was on the SUPPLY side. It can be either, and SUPPLY side is non-standard. But apparently fine. Knowing that, I had to make sure the Flow Arrow on the pump (I have the internal check valve version) faced toward the flow of the water which in my case was up and away from the boiler given it is a SUPPLY pipe. 3) to get the electrical on the correct side for my install, I had to remove the 4 pump bolts with an allen wrench, and pivot the entire pump and install back onto the base. No big deal, but worth knowing this if you need do the same. The electrical was easy. 2 wire nuts. White to white and in my case, Black to yellow. 4) This may be unique to my situation but the reason I was replacing the pump was a loud humming noise from that particular old circulator. I was shocked to hear the same noise there when I was done with my install. Another hour of research found a helpful video suggesting I purge air and water from that zone. Simply opened the Return line water valve and dumped it into a 5 gallon bucket. Apparently that got the air out. My autofill slowly replaced my depleted water, ie, in my case I didn't have to do anything in terms of refilling my boiler. So all is working great now. Nice and quite and pipe is hot on both sides of the pump meaning I got the trapped air out. Hopefully this saves you some research time.
Helpful Report
Posted 4 years ago
Works like a charm. Easy to install.
Helpful Report
Posted 4 years ago
Exactly what I needed for the wood boiler. Fast shipping, and no worry about it being a fake. THey also included a really nice little gift my wife took right away... ;)Thanks for the speedy quality service!
Helpful Report
Posted 4 years ago
It made an easy replacement of the one that had stopped working.
Helpful Report
Posted 4 years ago
Extremely easy to install .. just follow instruction. Four bolts and electric wire.
Helpful Report
Posted 5 years ago