Vulcan Thrasher Air BikeAir Bike DescriptionPre-Order. This item is estimated to be in stock January 27th to February 15th Please review FAQS The Vulcan Thrasher Air Bike is a commercial-grade heavy-duty bike that can be utilized in any training environment. The robust steel frame and solid mechanics ensure it will last a lifetime with repeated use. Air Bike Specifications: *Measurements are approximations Thrasher Frame: Length: 44" Width: 24" Height: 55" Weight: 137 lbs Seat Length: 12" Seat Height: 31" to 43" Monitor Length: 12" Belt driven Equipped with wheels for easy transport Water bottle included Heart rate monitor included Weight Capacity: 160 kilograms - 350 lbs Air Bike Operation and Programs: Quick Start Operation Under the STAND BY display, the user can enter "QUICK START" mode by pressing the "START" button. And then "TIME, DISTANCE, CALORIES" will ready to count up from zero. After starting the machine, the level of resistance can be adjusted manually. The system will pause counting TIME/DISTANCE/CALORIES if not receiving RPM signals. The system will continue previous counting once receiving RPM signal. While using, pressing "STOP" button will cease the operation of the console. Interval Program A. Under STANDBY DISPLAY, pressing "INTERVAL" button one time can enter default setting 20/10 program; pressing two times continuously can do the setting in Interval 20/10 program; pressing three times continuously can enter Interval Custom Program to set your own settings. 1. Setting interval laps on Interval 20/10 Program Under operating status, when choosing Interval 20/10, Internal 0/10 display will blink, the user can do the setting using "UP/DOWN" button. Pressing "ENTER" when setting is finished and then press "START" to run the program. 2. The processing mode after "START" When pressing "START" the program will operate based on WORK TIME 20 seconds/REST TIME 10 second, Interval takes record on each cycle until reaching the setting laps. 3. Setting Interval laps on Interval 10/20 program Under STANDBY mode, when choosing INTERVAL 10/20 program, "INTERVAL 0/10" display will blink. Use "UP/DOWN" button to do the setting. Press "ENTER" when finishing the setting and then press "START" to start the work out. 4. Processing mode after "START" When pressing START the program will operate based on WORK TIME 10 seconds/REST TIME 20 seconds, interval takes record on each cycle until reaching the setting laps. 5. Operation on INTERVAL CUSTOM mode Under STANDBY DISPLAY when choosing INTERVAL CUSTOM WORK TIME will blink. 6. Setting WORK TIME Use UP/DOWN button to set the time on WORK TIME. Press ENTER when finishing the setting, the program will switch to display on the next setting column. 7. Setting REST TIME Use UP/DOWN button to set REST TIME. Press ENTER when the setting is finished. The program will switch to display on the next setting column. 8. Setting on INTERVAL LAPS Use UP/DOWN button to set the interval laps. Press ENTER when the setting is finished. Press START to begin the work out. 9. The processing mode after START When processing START the program will operate based on WORK TIME/REST TIME the user has set, Interval takes record on each cycle until reaching the setting laps. Target Time Program B. Under STANDBY DISPLAY, pressing TIME program will enter the operation of this program. 1. Setting TIME When choosing TIME PROGRAM and pressing ENTER the program will switch to the default time of 30 seconds in blinking display. Press UP/DOWN button to set TIME or not change the default time, press ENTER to save the setting. Pressing START if the SPM signal shows after pulling the string, the program starts operating. 2. The Processing mode after START Under processing mode, TIME counts in decrement, DISTANCE/CALORIES counts in increment. Console will stop functioning when pressing STOP during operation. Target Distance Program C. Under STANDBY DISPLAY, press DISTANCE program to enter setting of this program. 1. Setting Distance Choose DISTANCE program and press ENTER, program will switch to the default distance setting of 5.00 and display blinking Press UP/DOWN button to set DISTANCE or not changing the default distance. Press ENTER to save the setting. 2. The Processing mode after START Under processing mode, DISTANCE display counts in decrement, TIME/CALORIES count in increment Console will stop function when pressing STOP during operation. Target Calories Program D. Under STANDBY DISPLAY, press CALORIES program to enter setting of this program. 1. Setting CALORIES Press UP/DOWN button to set CALORIES or not changing the default calories. Press ENTER to save the setting. 2. The Processing mode after START Under processing mode, CALORIES display counts in decrem
About Vulcan Strength Training Systems:
Vulcan Strength Training Systems is US veteran owned company and primary supplier and innovator of high quality strength training equipment. Vulcan Strength Bumper Plates, Olympic Barbells, Kettlebells, Squat Stands, Rigs and Racks are used in Crossfit and Olympic weightlifting gyms all over the world.
Visit Product PagePhone:
8779864313
Email:
vulcan@vulcanstrength.com
Location:
655-H Pressley Rd,
Charlotte
North Carolina
28217