Login
Start Free Trial Are you a business? Click Here

Taco 0012-F4-1 Cartridge Circulator Pump, 50 gpm, 115 VAC, Hydronic Heating Reviews

4.7 Rating 82 Reviews
Read Plumbing Supply and More Reviews

The Taco 0012-F4-1 cartridge circulator pump delivers exceptional hydronic circulation performance through its precisely engineered 52 gallon-per-minute flow capacity and robust cast iron construction. This MPN 0012-F4-1 model represents advanced centrifugal pump technology specifically calibrated for installations requiring substantial liquid movement through heating system infrastructure. The pump operates on 115-volt alternating current at 1.33 amperes, driving a 3250 revolution-per-minute motor that generates 1/8 horsepower output through its single-phase 60 Hertz electrical configuration. Measuring exactly 8.5 inches in height, 5.5 inches in width, and 9 inches in depth, this compact circulator incorporates a unique field-replaceable cartridge assembly containing all operational components for simplified maintenance protocols. The unit achieves a maximum head pressure of 14.5 feet while maintaining flow rates between zero and 52 gallons per minute, making it ideal for applications demanding high-volume water circulation through boiler systems, radiant underfloor heating networks, and commercial water heating installations. With a maximum working pressure rating of 150 pounds per square inch, this pump handles demanding hydronic applications where consistent thermal energy distribution remains critical for system efficiency and occupant comfort throughout residential and light commercial facilities. Cast Iron Construction & Non-Metallic Impeller Engineering for Hydronic System Durability The Taco 0012-F4-1's cast iron body construction provides superior structural integrity and exceptional thermal conductivity for closed-loop heating system applications. Cast iron material selection ensures optimal heat dissipation characteristics while maintaining dimensional stability across the pump's operational temperature range of 40 degrees to 230 degrees Fahrenheit. The ferrous metal housing withstands continuous thermal cycling without warping or degradation, protecting internal components from environmental stressors and maintaining alignment tolerances essential for friction-free operation throughout decades of service life. This specific model incorporates a non-metallic impeller design that eliminates galvanic corrosion concerns while reducing operational noise compared to traditional metal impeller configurations. The polymer-based impeller material resists chemical attack from glycol-based antifreeze solutions commonly added to hydronic heating systems for freeze protection and corrosion inhibition. Unlike stainless steel or bronze impellers that can develop pitting or erosion when exposed to oxygenated water conditions, the non-metallic impeller in this 0012-F4-1 maintains its geometric profile and pumping efficiency over extended operational periods. Carbon bearing technology integrated into this circulator's design provides self-lubricating functionality that eliminates mechanical seal requirements and associated maintenance procedures. The bearing material's natural lubricity reduces friction between rotating and stationary components without requiring external lubrication systems or periodic service interventions. This engineering approach significantly extends mean time between failures while reducing total cost of ownership for building operators managing multiple hydronic circulation points across large residential complexes or commercial heating installations requiring reliable year-round performance. Replaceable Cartridge Assembly Containing Motor, Impeller & Bearing Components for Service Efficiency The revolutionary cartridge design in the Taco 0012-F4-1 consolidates all moving components into a single field-replaceable assembly measuring 7.5 inches in length. This cartridge contains the motor rotor, non-metallic impeller, carbon bearing assembly, and shaft components within a sealed housing that can be removed and replaced without disturbing the pump's flange connections or piping infrastructure. Maintenance technicians can restore full operational capability by installing a replacement cartridge assembly (part number 0012-011RP for cast iron models) in approximately 15 minutes, dramatically reducing system downtime compared to complete circulator replacement procedures. The cartridge extraction process requires only basic hand tools and involves removing four hex-head bolts securing

Visit Product Page
“We purchased this as a replacement pump for our outdoor wood furnace. We use it to heat our grandchildren's above ground swimming pool. It has been a cold and rainy Spring and Summer and the kids have been able to enjoy the heated pool no matter how cool the temperature. When the current one quit, they were disappointed that they would not be able to swim, but fortunately, this pump arrived only days after placing the order. Easy to install and they are back to using the pool everyday.”
Helpful Report
Posted 7 years ago
“Easy to install. Replaced an old B&G motor and this fit in perfectly and does the job almost silently. This is the second Taco motor I have used.”
Helpful Report
Posted 7 years ago
“Purchased as spares, after a failure at my son's house, my system have 6 zones about 10 years old, I figured it would be a good investment, to have a back-up on hand”
Helpful Report
Posted 7 years ago
“Very affordable!”
Helpful Report
Posted 7 years ago
“I have a multi-zone + hot-water heating system with 2 pumps. I had to replace the other one a few years back, was $500 for the pump. This pump is more basic, it turns on with the furnace, where the other has thermostat control.”
Helpful Report
Posted 8 years ago
“I liked most that it worked. I liked least that the flanges were off 90 degrees from what I thought I ordered. - A dilemma I resolved by turning the fittings on the shut-offs my furnace guy had the foresight to install on each side of my pumps. [ If you don't have them, install shut-offs when you replace the pump this time. I can't imagine the headache you'd get having to drain and refill your system. ]”
Helpful Report
Posted 8 years ago
“I had this model pump on my boiler, and my original pump lasted 9 plus years. When my circulating pump went out, I realized the local vendors that sell these do not sell them to general public due to local city ordinances. As a result, I had to call my heating and cooling guy to essentially bolt my new pump on and wire it. I purchased this unit as a spare so that I would never have to get an expensive bill for such a simple repair. This pump truly is a simple bolt on install provided mounting flanges are in place. The pump does not come with mating flanges, and those have to be purchased separately if needed. The newer pump I had installed looked identical to the one it replaced. Hopefully, the reliability remains the same.”
Helpful Report
Posted 8 years ago
“Exact replacement of my old Taco 007-F5 circulator it even came with new gaskets. I removed my old circulator and the new one bolted up right in place of the existing one with no modifications. I wired it up and turned on my furnace and after my furnace heated up, the circulator turned on and worked perfectly. The new circulator is also very quite. Overall great product, I would definitely recommend purchasing this unit if your old one goes bad or if your looking for a new circulator to use on your furnace installation.”
Helpful Report
Posted 8 years ago